Torque
We are almost ready to describe an equation for the torque M at the rotor. A torque arises when the stator current is offset from a magnetic field by an angle γ. Magnetic poles then arise at the stator that attract or repel the rotor. The angle between stator current (stator magnetic field) and rotor magnetic field is expressed in d/q coordinates. According to our considerations so far, an angle of γ = 90° is optimal. Then the rotor field lies in the d direction and the stator current (and thus the stator field) in the q direction. This generates a torque. In general, for anticlockwise rotation:
A q-current together with a d-field generates an anticlockwise torque. You already know that. A d-current together with a field in the q direction also generates a torque, but in the wrong direction. That is why we consider the torque from negative d-current and positive q-field. Both effects are added (superposition). Next, let us insert formulas for the flux linkages:
The torque is larger when more magnetic field–current pairs pull on the rotor at the same time. It is therefore proportional to the number of pole pairs p and the number of coil pairs m. The following applies (without derivation):
We expected the first term of the torque equation. It represents the “synchronous torque”. The second summand is strange. The difference between the inductances in the d and q directions, multiplied by the product of the currents in the d and q directions, also gives a torque. This torque is called the “reluctance torque”.
Synchronous torque
The synchronous torque describes the attraction of the rotor magnet by the rotating stator magnetic field. So far we have only ever considered this force. We first examine how this force changes when the stator magnetic field points in different directions. The rotor is always aligned with its north pole in the d direction. We vary the angle γ between stator field and rotor field:

In the left figure, the stator magnetic field points in the direction γ = 45°. The north pole of the rotor is attracted by the south pole of the stator. The torque is directed anticlockwise. We arbitrarily define this direction as positive. At γ = 135° in the right figure the torque is also positive, because the south pole of the rotor is pushed away anticlockwise by the south pole of the stator field.

At γ = 270° in the left figure, the rotor turns the other way, i.e. clockwise. At γ = 0° (right figure) and γ = 180° it does not turn at all. The intensity of the torque depends on the distance of the stator field from both poles of the rotor magnet. Its magnitude is at its maximum at γ = 90° and γ = 270°, because there the stator field acts on both magnetic poles of the rotor. If we plot the intensity and direction of the synchronous torque against the angle γ, the following picture results:

If we consider only the synchronous torque, the control angle γ = 90° is optimal for our direction of rotation. For this, 100% of the current must flow in the q direction.
Reluctance torque
For an intuitive explanation of the reluctance torque, we modify the rotor. First we consider a rotor consisting only of an iron disc without a permanent magnet on it. No matter how the stator current flows, the rotor does not turn. It lies in a constantly changing magnetic field, but the field simply passes through it without causing any movement.
Now we consider a plastic rotor in which an elongated piece of iron has been inserted instead of the permanent magnet. The plastic does not conduct the magnetic field. The iron does. The iron aligns itself in the magnetic field; it is attracted by the stator magnetic field. The rotor turns with the stator field, even though no permanent magnet is glued onto it. A torque acts even then – the reluctance torque.
For this, materials with different magnetic conductivity must be present on the rotor. In one direction we need good magnetic conductivity, and in the other direction less good magnetic conductivity. Iron conducts the magnetic field well. Plastic, air and permanent magnets conduct it poorly.
Another example is a nail pivoted at its centre and lying in the stator magnetic field. It turns as soon as the stator field turns. A nail is attracted by both the magnetic north pole and the south pole. That distinguishes it from a permanent magnet. Our rotor conducts the magnetic field particularly well in the q direction. That is why, for the illustration, the tip of the nail also points in the q direction.

Let us look at the figure above. The nail is drawn in grey. It is held in place and the stator field is rotated around it. The direction of the stator field is drawn as a red arrow. The angle γ lies between the nail and the stator field. As an example, the stator field is drawn at γ = 45°. Let us consider the torque M acting on the nail. Its tip is attracted more strongly by the stator magnetic field than its head. The tip of the nail is moved clockwise towards the red arrow.
In the figure below, the stator magnetic field points in the direction γ = 135°. The needle is moved in the opposite direction. The direction of movement of the needle depends on the direction of the stator field.

Next, let us look at the problem more generally. The direction of movement is given for all regions of the stator field relative to the nail position as a function of the angle γ. For this we slowly rotate the direction of the red stator field phasor anticlockwise and consider in which direction the nail is attracted by the stator field. A positive torque means that the nail is turned anticlockwise. A negative torque means that the nail is moved clockwise.

| Angle γ | Torque | Description |
|---|---|---|
| 0° | \(M = 0\) | The nail is attracted equally strongly at tip and head |
| 0° < γ < 90° | \(M < 0\) | The tip of the nail is pulled towards I |
| 90° | \(M = 0\) | The nail already lies in the stator field direction |
| 90° < γ < 180° | \(M > 0\) | The tip of the nail is pulled towards I |
| 180° | \(M = 0\) | The nail is attracted equally strongly at tip and head |
| 180° < γ < 270° | \(M < 0\) | The head of the nail is pulled towards I |
| 270° | \(M = 0\) | The nail already lies in the stator field direction |
| 270° < γ < 360° | \(M > 0\) | The head of the nail is pulled towards I |

The intensity of the torque depends on the distance between the effective end of the nail and the magnetic field. The reluctance torque acts in both directions of rotation. It accelerates the rotor and brakes it. It repeats at γ = 180. With the angle γ we can set whether it is to act positively or negatively.
The reluctance torque acts only when there is both d-current and q-current. If the angle γ coincides with the d or q axis, the reluctance torque is 0. Let us look at the torque equation again:
The product of d- and q-current changes sinusoidally with γ at twice the frequency. This agrees with the graph of the reluctance torque. Now let us return to the electrical machine with permanent magnets on the rotor:
Because of the low material coefficient µr, the rotor is magnetically poorly conductive where the permanent magnet is located. Overall it behaves like a nail in the rotating magnetic field aligned in the q direction + like a permanent magnet in the rotating magnetic field aligned in the d direction (N).

The direction dependence of the magnetic conductivity in the rotor is described in the torque equation by the term Ld – Lq. The term describes how pronounced the nail effect is.
To get more torque per unit of current out of the machine, we use the reluctance torque. For this, we design rotors so that the inductances are as direction-dependent as possible. Then the term Ld – Lq becomes large.
Total torque
The total torque of the rotor is therefore made up of two components. The synchronous torque arises because the magnetic north pole of the stator attracts the south pole of the rotor. It is at its maximum at γ = 90°. That is why we impress q-current into the stator. The reluctance torque arises when the magnetic conductivity of the rotor in the d direction differs from that in the q direction. For Ld < Lq it is at its maximum at γ = 135° and at γ = 315° (180° further round the circle).
The optimal stator current therefore does not point in the direction γ = 90°. Depending on the machine parameters, the optimal angle lies in the range γ = [90° … 180°]. In the following example, the peak value of the reluctance torque is half as large as that of the synchronous torque.

In the right figure, the total torque is drawn in green as the sum of the synchronous torque (blue) and the reluctance torque (red). The optimal control angle is about γ = 120°. There the total torque is at its maximum and positive. What does this mean for controlling the motor? On the left you see the division of the stator current into d and q components for γ = 120°.
For Ld < Lq, the term Ld – Lq is negative. For the reluctance torque to act positively, the product of the currents must be negative. The q-current for the synchronous torque is positive. So we need an additional negative d-current for the reluctance torque. Rotating the stator current phasor from 90° to 120° in the example above also requires negative d-current. So formula and phasor diagram agree.