Summary
The following formulas were derived in the chapter on pole compensation:
Principle of compensation
A behaviour of the plant is cancelled by the opposite behaviour of the controller:
\[
\begin{gathered}
\text{I behaviour: } \frac{1}{s},\quad \text{D behaviour: } s,\quad \text{Combination: } s \cdot \frac{1}{s} = 1 \\[6pt]
\text{PT1 behaviour: } \frac{1}{1 + \tau s},\quad \text{Compensation: } 1 + \tau s,\quad \text{Combination: } (1 + \tau s) \cdot \frac{1}{1 + \tau s} = 1
\end{gathered}
\]
PID controller for compensation
\[
H_{\mathrm{PID}} = \frac{u(s)}{e(s)} = k_{PR} + k_{IR} \cdot \frac{1}{s} + k_{DR} \cdot s
\]
Example: plant with I behaviour and PT1 behaviour (τ = 1). The PD part of the controller compensates the PT1 behaviour:
\[
\begin{gathered}
A = H_{\mathrm{PID}} \cdot \frac{1}{s} \cdot \frac{1}{1 + s} \\[6pt]
\text{Goal: } H_{\mathrm{PID}} = 1 + s \rightarrow k_{PR} = 1,\ k_{IR} = 0 \text{ and } k_{DR} = 1 \\[6pt]
A = (1 + s) \cdot \frac{1}{s} \cdot \frac{1}{1 + s} = \frac{1}{s} \\[6pt]
H_{\mathrm{FÜ}} = \frac{1}{1 + \frac{1}{A}} = \frac{1}{1 + s} \\[6pt]
\text{Controlled system with PT1 behaviour with } \tau = 1
\end{gathered}
\]