Learning Content and Theses

Platform for digital learning at HSHL

Space Vectors

Alternating quantities can be drawn and calculated either as time waveforms, as RMS values or as complex phasors. Each form of representation has advantages and disadvantages. Depending on what is to be shown, I switch the form of representation. We compare the forms of representation using the following example signal:

\[ \begin{gathered} f = 50\,\mathrm{Hz},\; T = 20\,\mathrm{ms} \\[4pt] \hat{u} = 325\,\mathrm{V},\; \varphi = 30^\circ;\; \varphi = \frac{\pi}{6} \\[4pt] u(t) = \hat{u} \cdot \sin(\omega t + \varphi) = 325\,\mathrm{V} \cdot \sin\left(\omega t + \frac{\pi}{6}\right) \\[4pt] U = U_{\mathrm{eff}} = \frac{\hat{u}}{\sqrt{2}} = \frac{325\,\mathrm{V}}{\sqrt{2}} = 230\,\mathrm{V} \\[4pt] u(\omega) = \hat{u} \cdot e^{j\varphi} = 325\,\mathrm{V} \cdot e^{j\frac{\pi}{6}} \\[4pt] \mathrm{Re}\{u(\omega)\} = \hat{u} \cdot \cos(\varphi) = 281\,\mathrm{V} \\[4pt] \mathrm{Im}\{u(\omega)\} = \hat{u} \cdot \sin(\varphi) = 162\,\mathrm{V} \\[4pt] u(\omega) = 281\,\mathrm{V} + j162\,\mathrm{V} \end{gathered} \]

Time waveform

We can easily imagine the time waveform. It can be measured with an oscilloscope in the lab. So it is the form of representation that we can “experience”. The time waveform is unsuitable for calculation, because calculating with sinusoidal quantities is unnecessarily complicated. In the time waveform we see the parameters peak value and phase angle. We also see immediately if a waveform is not sinusoidal (which we avoid in this tutorial). Peak value, phase angle and time shift can be determined graphically.

Time waveform of the voltage u(t) with peak value 325 V and period 20 ms

RMS value

The RMS value of a sinusoidal quantity is always constant. With it we can capture the intensity or size of the signal with a single numerical value. However, the phase shift of the signal is lost.

Phasor

The complex phasor, or the complex calculation of sinusoidal quantities, is ideal for calculations. Phasors contain the peak value (signal intensity) in the length of the phasor. The phase is contained in the direction in which the phasor points in the complex plane. A phasor contains all relevant information about the signal.

Two complex quantities can easily be added or subtracted graphically by attaching two phasors to each other graphically. In component form, two complex numbers can easily be added or subtracted.

Two complex quantities in polar form can be multiplied (divided) by multiplying (dividing) the magnitudes and adding (subtracting) the phases. Graphically, this is achieved by rotating and stretching the phasor.

Graphical solutions are quickly found with phasors. This helps enormously with understanding and is often faster than calculation.

Phasors with RMS values

In the fundamentals of electrical engineering, the length of a phasor corresponds to the peak value of the time waveform. In drive technology and power supply, however, calculations are almost always done with RMS values. That is why there is also the representation of RMS values as phasors. The length of the phasor then corresponds to the RMS value of the time waveform. As soon as capital letters appear in phasors, they are RMS phasors.

Phasor of the voltage as peak value u(ω) with 325 V and as RMS value U(ω) with 230 V

Graphical addition and multiplication with phasors

Let us consider two phasors (RMS values). They are added graphically. Length and direction can be determined directly graphically. For this, the phasors are drawn one after the other:

\[ \begin{gathered} U_1 = 230\,\mathrm{V},\; \varphi_1 = 0 \\[4pt] U_2 = 230\,\mathrm{V},\; \varphi_2 = \frac{\pi}{2} \\[4pt] U_3 = U_1 + U_2 \end{gathered} \]
Graphical addition of the phasors U1 and U2 to U3

As an example of graphical multiplication, we look for the voltage across an inductor. The direction of a product of two phasors can be determined graphically, the length cannot. For the length, we multiply the magnitudes of the two phasors mathematically. So in the consideration below we determine only the direction of U:

\[ \begin{gathered} \text{Example values:} \\[2pt] I = j100\,\mathrm{A} = 100\,\mathrm{A} \cdot e^{j\frac{\pi}{2}} \\[4pt] Z_L = j\omega L = j10\,\Omega = 10\,\Omega \cdot e^{j\frac{\pi}{2}} \end{gathered} \]

\[ \begin{gathered} \text{Calculated solution:} \\[2pt] U = I \cdot Z_L = 100\,\mathrm{A} \cdot e^{j\frac{\pi}{2}} \cdot 10\,\Omega \cdot e^{j\frac{\pi}{2}} = 1\,\mathrm{kV} \cdot e^{\left(j\frac{\pi}{2} + j\frac{\pi}{2}\right)} = 1\,\mathrm{kV} \cdot e^{j\pi} = -1\,\mathrm{kV} \end{gathered} \]

\[ \begin{gathered} \text{Graphical solution to determine the direction of } U\text{:} \\[2pt] \text{Start in the direction of the current } I \text{ (upwards, } e^{j\frac{\pi}{2}}\text{)} \\[4pt] \text{Then } Z_L \text{ rotates by } j, \tfrac{\pi}{2} \text{ or } 90^\circ \text{ anticlockwise} \\[4pt] U \text{ then points in the direction } -1 \end{gathered} \]
Graphical determination of the direction of U: the current I points upwards, jωL rotates by 90° anticlockwise

In the figure above, lengths play no role, only directions. We determine the direction of U from I multiplied by Z. According to the task, the direction of I points upwards. The direction of Z rotates the direction of I by the rotation operator j. In multiplication, the direction of the product results from the sum of the directions of the factors. In our minds, we place ourselves on the direction of I and turn 90° to the left relative to it. That is the direction of the voltage.

The graphical solution is mathematically sloppy, because we draw current, voltage and impedance in one phasor diagram with uniform axes. That does not matter here; it is only about showing how the direction of U can be determined graphically. With this method we determine directions graphically very quickly, which we can use to check the plausibility of our calculations.

Space vectors and stator coils

Two opposing coils, each with opposite current amplitude, generate a magnetic field that acts in one spatial direction. It can be of different strength in this direction. And it can change sign; then it points in exactly the opposite direction. The direction of action still lies on the line between the coils. The magnetic field cannot act in any other direction, because the magnets are permanently installed on the stator.

With the 6 coils on the stator we can generate magnetic fields in three directions. With positive current, we have these three directions available:

Directions of the magnetic fields of the stator currents φ1, φ2 and φ3 at the stator
Richtung \(\varphi_1\) = direction \(\varphi_1\) · Richtung \(\varphi_2\) = direction \(\varphi_2\) · Richtung \(\varphi_3\) = direction \(\varphi_3\) · Richtung = direction

If only a magnetic field pointing, for example, to the right is needed, we can generate it with a positive current at coil 1. Then the current at coil 4 is automatically negative. We leave the other currents off.

Magnetic fields are superimposed. They can then be added like vectors to a total field. If a magnetic field is to point in another direction, we combine magnetic fields in the three available directions.

Stator current phasor

In drive technology, magnetic fields are visualised via current phasors. The direction of the magnetic field is mapped (in a physically somewhat sloppy way) onto a direction of the stator current. So when we speak of a stator current direction, we always mean the direction of the resulting magnetic field.

We leave the coils on the stator behind and consider only directions in space. In stator coordinates, the three possible current directions point in the directions 0° (current 1), 120° (current 2) and 240° (current 3).

Directions of the currents i1, i2 and i3 in stator coordinates
Stator-Koordinaten = stator coordinates · Richtung i_1 = direction i_1 · Richtung i_2 = direction i_2 · Richtung i_3 = direction i_3 · Koordinaten = coordinates · Richtung = direction

We superimpose the stator currents vectorially (again in a physically sloppy way) to a total stator current. By this we mean that the magnetic fields add up vectorially. So from the three coil currents we form a total current phasor that indicates the total direction and total intensity of the currents in the three stator coils.

We can superimpose sinusoidal current waveforms at the stator coils by hand at fixed points and look at the direction and intensity with which the resulting magnetic field acts. The expectation is that the magnetic field is always 90° ahead of the rotor magnetic field.

As an example, we consider the currents at rotor angle ΩRotor = 90° or π/2. At this point, according to the time diagram at the bottom left, i1 is at its maximum and positive. The currents i2 and i3 are half as large and negative. In the middle phasor representation, adding the three individual current phasors gives a total current phasor that points to the right.

In the last chapter we found: with a positive current at coil 1, we generate a magnetic south pole inside coil 1, towards the rotor. If we transfer this to the total current phasor at ΩRotor = 90°, the south pole of the stator field points in the direction of the total current phasor.

Currents at rotor angle π/2: time waveform, addition of the current phasors to the total current iGes and resulting stator field
Richtung i_2 = direction i_2 · Richtung i_3 = direction i_3 · Statorfeld = stator field · Rotorfeld = rotor field

Stator and rotor fields are shown on the right of the figure. The stator field points to the right with a south pole (Ω = 0°). The rotor field points upwards with its south pole (Ω = 90°).

Then, as a second example, we consider the currents at rotor angle ΩRotor = 180° or π. At this point i1 = 0A. The current i2 is positive, i3 is negative. The magnitude of the currents is

\[ \begin{gathered} \omega t = \pi \\[4pt] i_2(t) = \hat{\imath} \cdot \sin(\omega t + \varphi) = \hat{\imath} \cdot \sin\left(\pi - \frac{2}{3}\pi\right) = \hat{\imath} \cdot \sin\left(\frac{\pi}{3}\right) = \hat{\imath} \cdot \frac{\sqrt{3}}{2} = 0.86 \cdot \hat{\imath} \\[6pt] i_3(t) = \hat{\imath} \cdot \sin(\omega t + \varphi) = \hat{\imath} \cdot \sin\left(\pi + \frac{2}{3}\pi\right) = \hat{\imath} \cdot \sin\left(\frac{5\pi}{3}\right) = -\hat{\imath} \cdot \frac{\sqrt{3}}{2} = -0.86 \cdot \hat{\imath} \end{gathered} \]

In the phasor representation, adding the three individual current phasors gives a total current phasor that points upwards.

Currents at rotor angle π: time waveform, addition of the current phasors to the total current iGes pointing upwards and resulting stator field
Richtung i_1 = direction i_1 · Richtung i_2 = direction i_2 · Richtung i_3 = direction i_3 · Statorfeld = stator field · Rotorfeld = rotor field · Ges = total

I have thus shown at two angles that the total current phasor lags 90° behind the rotor in the direction of rotation. The total current phasor indicates the direction and intensity of the stator field.

Space vector length

If we draw the stator current space vectors (yellow) for many angles, we find that they all have the same length. They are all longer by a factor of 1.5 than the peak value of a phase current. They all point to a circle. In our minds, we follow the current waveforms (left figure) in the direction of the rotor angle Ω. Then, in the right figure, we follow the dashed circle anticlockwise.

Stator current space vectors (yellow) for many rotor angles: all the same length, they lie on a circle

The phase currents change their value sinusoidally over Ω (blue, green and red). The total stator current phasor (yellow) is a rotating current phasor of constant length.

I find this result brilliant. Think about what it means for the machine: if we drive the coils with sinusoidal currents, superposition generates a total stator magnetic field that always has the same intensity and rotates continuously in a circle. These are the yellow arrows above that visualise the stator space vector over one revolution. They all have the same length, so the intensity of the magnetic field is the same for every angle. No matter where the rotor is, the force is always the same. So the rotor is moved round the circle with a constant torque. That is why this type of control ensures very smooth running of the machines; they do not judder.

This smooth running due to a constant force is the reason why machines are driven sinusoidally. That is why, historically, alternating current prevailed over direct current in power supply.

I also find this result mathematically fascinating. If you add three sinusoidal quantities with the same peak value and a 120° phase shift, you get a phasor that rotates in a circle.

You can find a good simulation of the space vector at the following: link

Download course as PDF

The PDF contains all pages of the course. Interactive content is only available on the website.