Multi-Pole Machines
So far, for simplicity, we have considered a machine with one permanent magnet and 6 coils. Drive engineers call this design a single-pole machine (p = 1) with 3 coil pairs (m = 3). The number of pole pairs p indicates the number of permanent magnet south poles on the rotor. The more pole pairs a rotor has, the less it judders in operation. Theoretically it does not judder at all when operated with three-phase current, but in practice this is not always true.
The number of coils is usually always increased by three coil pairs at a time. The coils are connected in series with the existing coils. So they get the same currents as the other coils.
The number of pole pairs and the number of coils can be changed independently of each other. Advantages and effects would go too far here. A machine with p = 2 pole pairs and m = 6 coil pairs looks like this:

Four permanent magnets are glued onto the rotor, each offset by 90°. 12 coils are installed in the stator. Coils with the same number receive identical current. After all, they always see the same stator magnetic field. The coil pairs remain 1/4, 2/5 and 3/6. Previously everything repeated every 360°. Now everything repeats every 180°. It is as if we had placed 2 rotors and 2 stators one behind the other.
What changes? The electrical speed ω is now twice as fast as the mechanical speed n of the rotor. The current already repeats after half a rotor revolution, because a north pole of the stator passes the coil every 180°. The south pole of the stator must run ahead of the north pole of the rotor by Ω = 45° instead of 90°. We do not look at this in more detail here, but it is not too complicated.
In this tutorial we only consider machines with p = 1 and m = 3.